KTEB-242T-UV-TP-PSD

1 or 2x 42W CFL | 120-277 Multivoltage | HPF | Program Start | Dual Wire Case

Product Description

Primary Lamp Type: CFTR42W/GX24q
Primary No. of Lamps: 2
Input Voltage: 120-277
Starting Method: Program
Power Factor: High
Warranty: 5 Years
BADGEBADGE

Lamp TypeNo. of LampsLine CurrentInput WattsMin Power FactorMax THDBallast FactorMin. Start Temp (ºC, ºF)Max Case Temp (ºC, ºF)Wiring Diagram
CFTR42W/GX24q 10.38-0.18470.96100.96-18, 075, 167P1-2
CFTR42W/GX24q 20.70-0.30840.98100.9-18, 075, 167P2-2
CFQ26W/G24q 20.45-0.21540.97100.9-18, 090, 194P2-2
CFS28W/GR10q10.29-0.14340.93151-18, 090, 194P1-2
CFTR26W/G24Xq 10.27-0.13320.95101-18, 090, 194P1-2
CFTR26W/G24Xq 20.45-0.21540.97100.9-18, 090, 194P2-2
CFTR32W/GX24q 10.35-0.13420.96100.96-18, 090, 194P1-2
CFTR32W/GX24q 20.56-0.25690.96100.9-18, 090, 194P2-2
FC12T5 (40W)10.37-0.17450.96101-18, 090, 194P1-2
FC12T5 (40W)20.69-0.30820.97100.95-18, 090, 194P2-2
FC9T5 & FC12T520.55-0.25670.98100.9-18, 090, 194P2-2
FC9T5 (22W)10.27-0.13310.93151.2-18, 090, 194P1-2
FC9T5 (22W)20.49-0.22590.97101.1-18, 090, 194P2-2
FT24W/2G1120.45-0.20540.98101-18, 090, 194P2-2
FT36W/2G1110.31-0.14370.95120.88-18, 090, 194P1-2
FT36W/2G1120.55-0.24660.98100.8-18, 090, 194P2-2
FT40W/2G11RS20.69-0.30820.98100.95-18, 090, 194P2-2
CFQ26W/G24q 10.27-0.13240.95101-18, 090, 194P1-2
FT40W/2G11RS10.37-0.17450.96101-18, 090, 194P1-2

Vendor Part # Notes
Advance TransformerICF-2S42
Universal Lighting TechnologiesC242UNVxxx
General Electric
Osram SylvaniaQTP 2x26/32/42CF/UNV M